Contact Site map Home
Polski Rosyjski Niemiecki

LABORATORY MUFFLE FURNACE TYPE FCF1S

Type FCF1S
Max. temp. [°C] 1150
Chamber dimensions [mm] width x height x depth 110 x 85 x 110
Volume [dm³] 1
Overall dimensions [mm] width x height x depth 295 x 445 x 501
Power [kW] 0,8
Weight [kg] 20,5
Supply voltage [V~] 230
Heating up time (1000°C) [min] 30
print
a specification
sheet
make an inquiry about this product
If you have any questions please contact us:
tel. 32 47 07 495
tel./fax 32 47 07 502
e-mail: czylok@czylok.com.pl

Muffle furnaces are designed to conduct thermal processes in the laboratory with a particular application in the conditions ofthe occurrence of aggressive environment in the chamber in the form of gases, dustchips, etc. The ceramic muffleseparates the heating elements from the inside of the heating chamber, provides longer service life and maintains a stabletemperatureIt is possible to equip the furnace with a temperature programmer type M or temperature regulator type P.

 TEMPERATURE PROGRAMMER TYPE M
   TEMPERATURE REGULATOR TYPE P
 

One four-and two single displays allow easy reading of the actual temperature of the object and set parameters. With the ability to program a delayed start time as well as the holding time, ie. to maintain furnace temperature for a certain time, it is possible to automatically carry out a series of burnings unattended. This gives you the opportunity to work egduring the night tariff for electricity or to heat-up the furnace to the required temperature ahead of time, avoiding unnecessary downtime. Has the ability to program the time (ie. speed) to reach the desired temperature. Characterized by a programmable 10 stages in each program of work, where the stage corresponds to the set temperature, the time to come to the temperature and time of annealing temperature setpoint. This enables the formation of burning curve for any given furnace with varying lengths of growth or fall of temperature over time.

 

Two four character displays allow easy reading of the actual temperature of the object and set parametersWith the ability to program a delayed start time as well as the holding time, ie. to maintain furnace temperature for a certain timeit is possible to automatically carry out a series of burnings unattended. This gives you the opportunity to work egduring the night tariff for electricity or to heat-up the furnace to the required temperature ahead of time, avoiding unnecessary downtime.

 

<< back

See other products in the category: Muffle

Type Max. temp. Chamber dimensions [mm] Volume Overall dimensions [mm] Power Weight Supply voltage Heating up time (1000°C)
[°C] width height depth [dm³] width height depth [kW] [kg] [V~] [min]
LABORATORY MUFFLE FURNACE TYPE FCF1S FCF1S 1150 110 85 110 1 295 445 501 0,8 20,5 230 30
LABORATORY MUFFLE FURNACE TYPE FCF2,5S FCF2,5S 1150 140 85 210 2,5 370 526 523 1,4 30 230 30
LABORATORY MUFFLE FURNACE TYPE FCF2,5SH FCF2,5SH 1300 140 85 210 2,5 370 526 523 1,6 30 230 30
LABORATORY MUFFLE FURNACE TYPE FCF5S FCF5S 1150 180 125 250 5 452 600 668 2,4 45 230 35
LABORATORY MUFFLE FURNACE TYPE FCF5SH FCF5SH 1300 180 125 250 5 452 600 668 2,4 45 230 35
LABORATORY MUFFLE FURNACE TYPE FCF7S FCF7S 1150 180 125 300 7 452 600 724 2,5 47 230 45
LABORATORY MUFFLE FURNACE TYPE FCF7SH FCF7SH 1300 180 125 300 7 452 600 724 2,8 47 230 45
LABORATORY MUFFLE FURNACE TYPE FCF12S FCF12S 1150 240 200 250 12 585 805 750 2,8 77 230 75
LABORATORY MUFFLE FURNACE TYPE FCF12SH FCF12SH 1300 240 200 250 12 585 805 750 3,3 80 230 75
LABORATORY MUFFLE FURNACE TYPE FCF22S FCF22S 1000 290 220 350 22 730 620 750 3,3 90 230 85
LABORATORY MUFFLE FURNACE TYPE FCF 26SH FCF 26SH 1300 240 200 550 26 685 645 1070 6 112 400 75
LABORATORY MUFFLE FURNACE TYPE FCF22SH FCF22SH 1300 290 220 350 22 770 680 860 4,5 130 230 40